Home / Products / 2D Micro Radiography System

2D Micro Radiography System

Introducing our state-of-the-art, flexible 2D Micro Radiography System, where Photonic Sciences’ industry-leading X-ray cameras deliver exceptional resolution at a microscopic level. With over 20 years of expertise in X-ray system design, we specialise in customising solutions to meet your unique needs. Our system is ideal for diverse applications, including medical R&D, non-destructive testing, archaeology, material science, electronics, and forensics

We offer two standard products to serve as the foundation for your custom X-ray imaging platform: For those requiring minute details, our High-Resolution system, featuring a dedicated microfocus X-ray source, can resolve features as small as 3 µm. For applications requiring exposures below 1 sec, active areas up to 95 mm diagonally and 30 µm resolution at the object, our Rapid Imaging system employs a powerful 50W minifocus X-ray source, enabling near 1:1 rapid high resolution imaging.

 

 

 

Features & Benefits

  • Complete System - Fully integrated, with table, for plug-n-play operation
    - no additional room preparation or services required
  • Fixed Focus Visual Camera - Aids in aligning the sample to the X-ray beam and
    selecting desired imaging area
  • Motorised Sample Mount - Automated sample scanning and positioning
  • sCMOS X-Ray Camera - Active area up to 65.5 x 65.5 mm, down to 25 µm
    resolution, and 58% peak QE
  • Air Cooled Source - Low maintenance, low cost, and low power
    requirements - run off a standard plug
  • Targeted magnification 1x to 10x variable magnification option for versatile
    systems which need flexible resolution
  • X-ray Safety Warning lights, x-ray beacons, and interlocks
    conforming to Health & Safety Standards
  • On-site/Remote Install and Training

Sample 2D Radiography Images

Vertical Laue System

2D radiography images from various samples taken at 60 kVp and 2s exposure, including a meal-worm head, PLD boards, and a resolution chart.

System Options

Resolution at the target 3 µm at 2.5W with 5x magnification, 5 µm at 8w with 5x magnification
Magnification range 5x to 10x
Area of illuminated target 7.34 mm2 at x5 magnification, 3.67 mm2 at x10 magnification
Typical exposure time (sample dependent) ~2s
Resolution at the target ~30 µm
Magnification range ~1:1
Area of illuminated target ~36.7 mm2 or 65.5 mm2
Typical exposure time (sample dependent) >1s

Contact Us

22 Theaklen Drive,
Saint Leonards-on-sea,
TN38 9AZ,
United Kingdom

Phone:
+44 (0)1424 444883